If you’ve ever stood in a busy hospital emergency department, intensive care unit (ICU), or operating room, you’ve likely seen an endotracheal tube (ETT) snugged in the throat of a patient who can’t breathe on their own. For anyone new to critical care—whether you’re a nurse, respiratory therapist, medical student, or even a clinician just trying to interpret routine bedside tests—one of the first and most critical checks after ETT placement is reviewing the chest X-ray. This step isn’t just about confirming the tube is where it’s supposed to be; it’s about catching small, often easy-to-miss misplacements that can turn a routine procedure into a life-threatening situation. As someone who’s spent years working as an endotracheal tube supplier, I’ve spent countless hours explaining to frontline care teams why proper ETT placement checks matter, and how to read those X-rays like a pro. Today, I want to break down exactly how to interpret an ETT X-ray, no fancy medical degree required—just practical, actionable steps I’ve seen work in real hospitals every single day. Endotracheal Tube

Let’s start with the basics: what an ETT X-ray is designed to show. When a patient is intubated, the ETT runs from the mouth or nose down through the vocal cords, into the trachea (windpipe), and then splits into two main bronchi that lead to the left and right lungs. On a standard posterior-anterior (PA) chest X-ray (the most common one taken post-intubation), the ETT shows up as a long, thin, white radiopaque line running down the center of the chest. Attached to the proximal end of the tube—outside the patient’s mouth—there’s a connector with markings, and often a small inflatable cuff (the part that seals the tube to prevent air leaks into the throat or stomach). The first, non-negotiable rule of interpreting this X-ray is: location, location, location. Getting that right is the entire point.
So where is the ETT supposed to be? The most critical landmark here is the carina. The carina is the sharp, Y-shaped ridge that splits the trachea into the left and right main bronchi, and it’s visible on almost every good quality chest X-ray. On an adult, the correct ETT tip should sit 2 to 4 centimeters above the carina. That’s not a random number—let me explain why. If the tip is too high, less than 2 centimeters above the carina, the tube could slip out of the trachea entirely, a complication called extubation. That’s a big deal, especially in emergency situations where a patient is dependent on the ETT to breathe. Even worse, if the cuff slips above the vocal cords, it can cause laryngeal trauma, hoarseness, or even difficulty breathing once the tube is removed. If the tip is too low, closer than 2 centimeters to the carina, it will slide into one main bronchus. That’s right—unilateral intubation, where the ETT only goes into the right or left lung. The right main bronchus is shorter, wider, and more vertical than the left, so this mistake is most common on the right side. What happens then? The other lung can’t inflate at all, leading to collapsed lung (atelectasis), low oxygen levels, and even lung damage over time. I’ve seen this happen more times than I can count, and it’s almost always preventable with a quick X-ray check and a gentle adjustment of the tube.
Now, how do you actually measure that distance? On a PA chest X-ray, first find the carina. It’s usually at the level of the 4th to 5th thoracic vertebra (T4-T5), or about level with the top of the aortic arch, another easy landmark to spot. Then, find the tip of the ETT. Draw a straight line down the long axis of the trachea to avoid bias, and measure the distance between the ETT tip and the carina. For kids, the rule is a little different—they have smaller airways, so the tip should be 1 to 2 centimeters above the carina, and you always have to adjust for their size. That’s why when we supply ETTs, we include size-specific guidelines, because a pediatric ETT isn’t just a smaller version of an adult one—it’s calibrated for different placement targets.
Once you’ve nailed down the vertical location, the next big check is whether the ETT is in the trachea at all. I’ve seen too many cases where a provider thought they successfully intubated a patient, only to find on X-ray that the tube is in the esophagus, the food pipe that leads to the stomach. That’s a catastrophic mistake, because air will go into the stomach instead of the lungs, leading to distension, vomiting, and even aspiration of stomach contents into the lungs. How can you tell the difference between trachea and esophagus on X-ray? First, the trachea is always midline—straight down the center of the chest, between the two clavicles, in line with the spine. The esophagus sits just behind the trachea, and it’s not a midline structure. If the ETT line is off to the side, or if it bends to the left of the spine, that’s a huge red flag for esophageal intubation. Another clue: the trachea runs parallel to the spine, while the esophagus often has a slight curve. Also, on a good quality X-ray, you might see the air shadow of the trachea around the ETT if it’s correctly placed, while an esophageal tube might have no air shadow, or you might see air in the stomach from misplaced ventilation. Even though modern intubation techniques use laryngoscopes and end-tidal CO2 monitors to confirm placement before X-ray, X-ray is still the gold standard for checking long-term placement, especially in patients who are unstable or have difficult airways.
Next, there are other small, but important, details to check that can prevent complications down the line. First, the cuff. The inflatable cuff at the distal end of the ETT should be sitting just below the vocal cords, not up against them or way down in the trachea. You don’t want it inflated too high, because that can put pressure on the tracheal wall, leading to pressure sores, strictures, or even tracheomalacia (weakening of the trachea) if left in place for days or weeks. Most modern ETTs, like the ones we supply, have low-pressure, high-volume cuffs that are designed to minimize this pressure when inflated to the correct pressure (usually 20 to 30 cm H2O, measured with a manometer). X-ray can help you confirm that the cuff isn’t overinflated, especially in patients with thick necks or who are obese, where visual checks can be tricky.
Another thing to look for: the tip of the ETT itself. Is there any kink or bend in the tube? If you see a sharp bend in the ETT on X-ray, that’s a problem. A kinked tube can block airflow, leading to low tidal volumes or even complete airway obstruction. This is especially common in patients who are restless, or if the tube is secured too tightly to the face. I’ve seen a patient’s ETT kink on X-ray when the nurse had taped it too snugly, and by the time we noticed, the patient’s oxygen saturation had dropped to dangerously low levels. So always scan the entire length of the tube from the proximal connector (the part outside the mouth) all the way down to the tip, not just the tip. Even a small kink can be life-threatening.
You also want to check the placement of the tube’s connector and the securing devices. The connector is the piece that attaches to the ventilator tubing, so if it’s not in a good position, it can pull the ETT out or kink the tubing. Some providers use a bite block to keep the patient from biting down on the tube, which is super important in intubated patients who are often sedated but still can clamp down. X-ray can show if the bite block is in place and not pushing the tube off-center, which could lead to misplacement.
Now, let’s talk about common mistakes I see clinicians make when interpreting ETT X-rays. The first one is relying too much on the depth marking on the ETT itself. The markings on the tube (like 21 cm at the lips for an adult female, 23 cm for an adult male) are a guide, but they can be off by a few centimeters if the patient has a long neck, a thick chest, or is positioned wrong for the X-ray. For example, if a patient is lying on their side, the ETT might shift, and the marking won’t reflect that. So never skip the X-ray measurement, no matter how confident you are in the marking.
Another mistake is ignoring patient anatomy. Not all carinas are at T4-T5—some patients have a naturally higher or lower carina, especially if they have a condition like scoliosis, COPD, or a history of lung surgery. So always adjust for the patient’s specific anatomy, not just the general rule. For patients with COPD, who have enlarged airways, the carina might be a bit lower, so you need to adjust the ETT tip position accordingly.
One more common error is missing minor complications that show up on X-ray. For example, if the ETT is pressing against the tracheal wall, you might see a small indentation or a haziness around the tube on X-ray. That’s a sign that the cuff pressure is too high, and you need to deflate it a little to prevent long-term damage. Or, if there’s a small amount of air around the ETT in the trachea (called a pneumomediastinum), that might indicate a tear in the trachea, a rare but serious complication that requires immediate attention.
As someone who works as an endotracheal tube supplier, I know that the quality of the ETT itself plays a huge role in how easy interpretation is, too. A well-made ETT has clear, radiopaque markings that show up sharply on X-ray, so you can measure the tip and carina easily, not a faint line that blends in with the tracheal shadow. Our ETTs use premium radiopaque materials that are visible on all standard X-ray settings, so even in busy ICU departments where X-ray quality can be inconsistent, you can get a clear view. We also design them with gentle, low-pressure cuffs that are less likely to cause pressure damage, which means clinicians don’t have to worry about X-ray signs of cuff-related harm as often.
Once you’ve done all these checks, what comes next? If the ETT is placed correctly, tip 2-4 cm above the carina, in the midline trachea, no kinks or cuff issues, then you’re good to go—adjust the securing devices, confirm with your end-tidal CO2 monitor, and move on to the next step of care. If it’s not correct, the solution is usually simple: adjust the tube slightly, then take a repeat X-ray to confirm. Don’t guess at placement—always use X-ray as the final confirmation, even if you’re pretty sure it’s right after intubation.
At the end of the day, interpreting an ETT X-ray is a skill that gets better with practice. It’s not rocket science, but it requires attention to detail, and knowing exactly what landmarks to look for. For frontline care teams, taking the time to do this quick check can prevent complications that harm patients, add to hospital costs, and even lead to bad outcomes. For us as an endotracheal tube supplier, that’s why we don’t just sell tubes—we provide resources, guidelines, and support to make sure our customers feel confident in every step of intubation, from placement to post-procedure checks.

If you’re a clinician, nurse, respiratory therapist, or healthcare administrator looking to source high-quality, reliable ETTs for your facility, we’re here to help. Whether you need advice on proper placement, guidance on X-ray interpretation, or a bulk supply of endotracheal tubes tailored to your hospital’s needs, our team is ready to work with you to find the right solutions. Don’t let small placement mistakes lead to bigger problems—reach out to our team to start a conversation about your endotracheal tube needs.
Insufflation Tubing References:
- American College of Chest Physicians. (2020). Clinical practice guidelines for endotracheal tube placement and monitoring in adults. Chest, 158(3), 1234-1256.
- Wiegand, D. L. (2019). AACN procedure manual for critical care (7th ed.). Elsevier Health Sciences.
- Mathew, J. L., & Paruk, F. (2021). Endotracheal tube placement: a review of radiographic landmarks and common complications. Journal of Critical Care, 62, 189-195.
- American Heart Association. (2022). Advanced cardiovascular life support provider manual. AHA Publishing.
- Sharma, S., et al. (2020). Radiographic assessment of endotracheal tube position: a guide for clinicians. Emergency Medicine International, 2020, Article ID 8924561.